Add HVAC Proposal Template eSigning with airSlate SignNow

Eliminate paperwork and automate document processing for more performance and limitless opportunities. Sign any papers from your home, quick and feature-rich. Experience a greater way of doing business with airSlate SignNow.

Award-winning eSignature solution

Send my document for signature

Get your document eSigned by multiple recipients.
Send my document for signature

Sign my own document

Add your eSignature
to a document in a few clicks.
Sign my own document

Do more online with a globally-trusted eSignature platform

Remarkable signing experience

You can make eSigning workflows intuitive, fast, and efficient for your clients and employees. Get your documents signed within a matter of minutes

Robust reporting and analytics

Real-time accessibility along with immediate notifications means you’ll never miss a thing. View statistics and document progress via easy-to-understand reporting and dashboards.

Mobile eSigning in person and remotely

airSlate SignNow enables you to sign on any system from any location, regardless if you are working remotely from home or are in person at your workplace. Each signing experience is flexible and easy to customize.

Industry polices and conformity

Your electronic signatures are legally binding. airSlate SignNow guarantees the top-level conformity with US and EU eSignature laws and maintains market-specific regulations.

Add hvac proposal template esigning, faster than ever

airSlate SignNow provides a add hvac proposal template esigning feature that helps enhance document workflows, get contracts signed immediately, and work smoothly with PDFs.

Helpful eSignature extensions

Take full advantage of simple-to-install airSlate SignNow add-ons for Google Docs, Chrome browser, Gmail, and much more. Try airSlate SignNow’s legally-binding eSignature capabilities with a mouse click

See airSlate SignNow eSignatures in action

Create secure and intuitive eSignature workflows on any device, track the status of documents right in your account, build online fillable forms – all within a single solution.

Try airSlate SignNow with a sample document

Complete a sample document online. Experience airSlate SignNow's intuitive interface and easy-to-use tools
in action. Open a sample document to add a signature, date, text, upload attachments, and test other useful functionality.

sample
Checkboxes and radio buttons
sample
Request an attachment
sample
Set up data validation

airSlate SignNow solutions for better efficiency

Keep contracts protected
Enhance your document security and keep contracts safe from unauthorized access with dual-factor authentication options. Ask your recipients to prove their identity before opening a contract to add hvac proposal template esigning.
Stay mobile while eSigning
Install the airSlate SignNow app on your iOS or Android device and close deals from anywhere, 24/7. Work with forms and contracts even offline and add hvac proposal template esigning later when your internet connection is restored.
Integrate eSignatures into your business apps
Incorporate airSlate SignNow into your business applications to quickly add hvac proposal template esigning without switching between windows and tabs. Benefit from airSlate SignNow integrations to save time and effort while eSigning forms in just a few clicks.
Generate fillable forms with smart fields
Update any document with fillable fields, make them required or optional, or add conditions for them to appear. Make sure signers complete your form correctly by assigning roles to fields.
Close deals and get paid promptly
Collect documents from clients and partners in minutes instead of weeks. Ask your signers to add hvac proposal template esigning and include a charge request field to your sample to automatically collect payments during the contract signing.
Collect signatures
24x
faster
Reduce costs by
$30
per document
Save up to
40h
per employee / month

Our user reviews speak for themselves

illustrations persone
Kodi-Marie Evans
Director of NetSuite Operations at Xerox
airSlate SignNow provides us with the flexibility needed to get the right signatures on the right documents, in the right formats, based on our integration with NetSuite.
illustrations reviews slider
illustrations persone
Samantha Jo
Enterprise Client Partner at Yelp
airSlate SignNow has made life easier for me. It has been huge to have the ability to sign contracts on-the-go! It is now less stressful to get things done efficiently and promptly.
illustrations reviews slider
illustrations persone
Megan Bond
Digital marketing management at Electrolux
This software has added to our business value. I have got rid of the repetitive tasks. I am capable of creating the mobile native web forms. Now I can easily make payment contracts through a fair channel and their management is very easy.
illustrations reviews slider
walmart logo
exonMobil logo
apple logo
comcast logo
facebook logo
FedEx logo
be ready to get more

Why choose airSlate SignNow

  • Free 7-day trial. Choose the plan you need and try it risk-free.
  • Honest pricing for full-featured plans. airSlate SignNow offers subscription plans with no overages or hidden fees at renewal.
  • Enterprise-grade security. airSlate SignNow helps you comply with global security standards.
illustrations signature

Your step-by-step guide — add hvac proposal template esigning

Access helpful tips and quick steps covering a variety of airSlate SignNow’s most popular features.

Using airSlate SignNow’s eSignature any business can speed up signature workflows and eSign in real-time, delivering a better experience to customers and employees. add HVAC Proposal Template esigning in a few simple steps. Our mobile-first apps make working on the go possible, even while offline! Sign documents from anywhere in the world and close deals faster.

Follow the step-by-step guide to add HVAC Proposal Template esigning:

  1. Log in to your airSlate SignNow account.
  2. Locate your document in your folders or upload a new one.
  3. Open the document and make edits using the Tools menu.
  4. Drag & drop fillable fields, add text and sign it.
  5. Add multiple signers using their emails and set the signing order.
  6. Specify which recipients will get an executed copy.
  7. Use Advanced Options to limit access to the record and set an expiration date.
  8. Click Save and Close when completed.

In addition, there are more advanced features available to add HVAC Proposal Template esigning. Add users to your shared workspace, view teams, and track collaboration. Millions of users across the US and Europe agree that a system that brings people together in one cohesive workspace, is the thing that organizations need to keep workflows performing effortlessly. The airSlate SignNow REST API allows you to integrate eSignatures into your app, internet site, CRM or cloud storage. Try out airSlate SignNow and get quicker, smoother and overall more efficient eSignature workflows!

How it works

Open & edit your documents online
Create legally-binding eSignatures
Store and share documents securely

airSlate SignNow features that users love

Speed up your paper-based processes with an easy-to-use eSignature solution.

Edit PDFs
online
Generate templates of your most used documents for signing and completion.
Create a signing link
Share a document via a link without the need to add recipient emails.
Assign roles to signers
Organize complex signing workflows by adding multiple signers and assigning roles.
Create a document template
Create teams to collaborate on documents and templates in real time.
Add Signature fields
Get accurate signatures exactly where you need them using signature fields.
Archive documents in bulk
Save time by archiving multiple documents at once.
be ready to get more

Get legally-binding signatures now!

What active users are saying — add hvac proposal template esigning

Get access to airSlate SignNow’s reviews, our customers’ advice, and their stories. Hear from real users and what they say about features for generating and signing docs.

Mass Daily Contract Sending
5
Administrator in Entertainment

What do you like best?

I like that I can easily send out bulk emails. It is very convenient to connect the documents to box in order to save them once they are signed. It is nice to be able to put out logo on the document when we send it out.

Read full review
Straightforward, easy-to-use signature software
5
Consultant in Marketing and Advertising

What do you like best?

The interface is really intuitive and makes it easy for me to upload documents, sign them, and forward them on to my clients for a final signature. airSlate SignNow is also more affordable than alternative signature applications.

Read full review
I work in legal Support Industries and service of process and signing proof is a daily routi...
5
Administrator in Legal Services

What do you like best?

the program is friendly to use when i invite my collegues to use this sysytem for signatures this makes it so easy for them once they accept the invitation. The signature is quick and it is sent back to me with clarity and it cuts the time and effort in getting the signed document back to me. This is less stressful for me and my business to get hings done in a timely manner and with efficency.

Read full review

Related searches to add HVAC Proposal Template esigning with airSlate airSlate SignNow

hvac bid proposal example
free hvac proposal template
hvac proposal template word
hvac installation contract template
hvac proposal software
good-better-best hvac proposal
hvac quote template pdf
free printable hvac proposal forms
video background

Esigning plumbing proposal template

Hey there guys, Paul here from TheEngineeringMindset.com. In this video, we're going to be looking at ductwork systems for mechanical ventilation. We're going to look at how to design a basic ventilation system with a full worked example. We'll also look at how to calculate the losses through the bends, the tees, the ducts and the branches, we'll consider the shapes in the material that the ducts are made from to improve the efficiency, and then lastly, we're going to look at how to improve the efficiency and optimize the design, using a freemium software for fluid flow simulation by SimScale. Methods of ductwork design, there are many different methods used to design ventilation systems, the most common ways being velocity reduction, equal friction and static regain. We're going to focus on the equal friction method in this example, as it's the most common method used for commercial HVAC systems, and it's fairly simple to follow. So we'll jump straight into designing a system. We use a small engineering office as an example and we'll want to make a layout drawing for the building which we'll use for the design and calculations. This is a really simple building. It has just four offices, a corridor, and a mechanical room. And the mechanical room is where we're going to have the fan, the filters, the air heaters or the air cooler. The first thing we'll need to do is calculate the heating and cooling loads for each room. I won't cover how to do that in this video, we'll have to cover that in a separate tutorial as it's a separate subject area. Once you have these figures, just tally them together to find which is the biggest load as we need to size the system to be able to operate at the peak demand. The cooling load is usually the highest load as it is in this case. Now we need to convert the cooling loads into volume flow rates, but to do that, we first need to convert this into mass flow rates, we use the formula M dot equals Q divided by CP, multiply by delta T, with M dot meaning the mass flow rate, the Q being the cooling load of the room, CP is the specific heat capacity of the air and delta T being the temperature difference between the design air temperature and the design return temperature, just to note that we will use a CP of 1.026 kilojoules per kilogram per kelvin as standard, and the delta T should be less than 10, and in this case, we're going to use eight degrees Celsius. We know all the values for this formula, so we can calculate the mass flow rate, and the mass flow rate is really just how many kilograms per second of air needs to enter that room. If we look at the calculation for room one, we see that it requires 0.26 kilograms per second. So we just repeat that calculation for the rest of the rooms to find all the mass flow rates. Now we can convert these mass flow rates into volume flow rates. To do that we need the specific volume or density of the air. We'll specify that the air needs to be 21 degrees Celsius, and we'll assume that it's going to be at atmospheric pressure of 101.325 kPa, we can look up the specific volume or density from our air properties tables, but I like to just use an online calculator as it's much quicker. So we just drop those numbers in and we get the density of air being 1.2 kilograms per meter cubed. You see that density has the units of kilogram per meter cubed, but we need specific volume which is meter cube per kilogram. So to convert that we just take the inverse which means to calculate the density or 1.2 to the power of minus one, you can just do that in Excel very quickly to get the answer of 0.83 meters cube per kilogram. Now that we have that we can calculate the volume flow rate, using the formula V dot equals M dot multiplied by V, where V dot equals the volume flow rate, M dot equals the mass flow rate of the individual room and V equals the specific volume, which we just calculated. So if we drop these values in for room one, we get the volume flow rate of 0.2158 meters per second. That is how much air it needs to enter the room to meet the cooling load. So just repeat that calculation for all the remaining rooms. Now we're going to sketch out our ductwork route onto the floor plan so we can start to size it. Before we size that we need to consider some things which will play a big role in the overall efficiency of the system. The first point we need to consider is the shape of the ductwork, Ductwork comes in round, rectangular, and flat oval shape. Round duct is by far the most energy efficient type and that's what we're going to use in our worked example later on. If we compare round duct to rectangle duct, we see that a round duct with a cross sectional area of 0.6 meters squared has a perimeter of 2.75 meters, a rectangular duct with equal cross sectional area of 0.6 meters squared, has a perimeter of 3.87 meters. The rectangular duct therefore requires more metal for its construction. This adds more weight and cost to the design. A larger perimeter also means that more air will come into contact with the material and this adds friction to the system. Friction in a system means a fan needs to work harder and this results in higher operating costs. Always use round duct where possible although in many cases the rectangular duct needs to be used as space is very limited. The second thing to consider is the material being used for the ducts. The rougher the material, the more the friction it will cause. For example, if we had two ducts with equal dimensions, volume, flow rate and velocity, the only difference being the material, one is made from standard galvanized steel the other from fiberglass. The pressure drop over a 10-meter distance for this example is around 11 pascals for the galvanized steel and 16 pascals for the fiberglass. The third thing we have to consider is the dynamic losses caused by the fittings. We want to use the smoothest fittings possible for energy efficiency. For example, use long radius bends rather than right angles as the sudden change in direction, wastes a huge amount of energy. We can compare the performance of different ductwork designs quickly and easily using CFD or computational fluid dynamics. These simulations on screen were produce using a revolutionary cloud-based CFD and FEA engineering platform by SimScale who have kindly sponsored this video. You can access this software free of charge using the links in the video description below, and they offer a number of different account types, depending on your simulation needs. SimScale is not just limited to ductwork design, it's also used for data centers, AEC applications, electronics design, as well as thermal and structural analysis. Just a quick look through their site and you can find thousands of simulations for everything from buildings, HVAC systems, heat exchangers, pumps and valves, to race cars and airplanes, which can all be copied and used as templates for your own design analysis. They also offer free webinars, courses and tutorials to help you set up and run your own simulations. If like me, you have some experience creating CFD simulations, then you'll know that this type of software is usually very expensive, and you would need a powerful computer to run it. With SimScale however, it can all be done from a web browser, as the platform is cloud-based, their servers do all the work and we can access and design simulations from anywhere which makes our lives as engineers a lot easier. So if you're an engineer, a designer, or an architect or just someone interested in trying out simulation technology, then I highly recommend you check out this software, get your free account by following the links in the video description below. Now, if we look at the comparison for the two designs, we have a standard design on the left and a more efficient design on the right which has been optimized using SimScale. Both designs use an air velocity of five meters per second, the color represents the velocity with blue meaning low velocity and red representing the higher velocity regions. We can see from the velocity color scale and the streamlines that in the design on the left, the inlet air directly strikes the sharp turns that are present in the system, which causes an increase in the static pressure. The sharp turns cause a large amount of recirculation regions when the duct's preventing the air from moving smoothly, the T section at the far end of the main duct causes the air to suddenly divide and change direction, there is a high amount of backflow here which again increases the static pressure and reduces the amount of air delivery. The higher velocity in the main duct which is caused by the sharp turns and sudden bends reduces the flow into the three branches on the left. If we now focus on the optimized design on the right, we see that the fittings used follow a much smoother profile with no sudden obstructions, recirculation or backflow, which significantly improves the air flow rate within the system. At the far end of the main duct, the air is divided into the two branches through gentle curved T section. This allows the air to smoothly change direction and thus there is no sudden increase in static pressure and the air flow rate to these rooms has dramatically increased. The three branches within the main duct, now receive equal airflow, making a significant improvement to the design. This is because an additional branch now feeds the three smaller branches, allowing some of the air to smoothly break away from the main flow and feed into these smaller branches. Now that we have decided to use circular ducts, made from galvanized steel, we can continue with the design. Label every section of ductwork and fitting with a letter. Notice we are only designing a very simple system here so I've only included ducts and basic fittings, I've not included things such as grills, inlets, flexible connections, fire dampers, et cetera. Now we want to make a table with the rows and columns labeled as per the example on screen now, each duct and fitting needs its own row. If the air stream splits such as with a T section, then we need to include a line for each direction. So just add in the letters to separate the rows then declare what type of fittings or ducts that corresponds to. We can start to fill some of the data in. We can first include the volume flow rates for each of the branches. This is easy, it's just the volume flow rates for the rooms which the branch serves. You can see on the chart I've filled that in now, then we can start to size the main ducts. To do this, make sure you start with the main duct which is furthest away, then we just add up the volume flow rates for all the branches downstream from this. For the main duct G, we just sum the branches L and I, for D, that's just the sum of L, I and F, and for duct A then it's the sum of L, I, F and C, so just enter those into the table. Now from the rough drawing, we measure out the lengths of each of the duct sections and the branches and enter this into the chart, and now we can begin to calculate the size of the ductwork. To do that we need a duct pressure loss chart, you can obtain these from ductwork manufacturers or from industry bodies such as CIBSE and ASHRAE. I've included links to these guides in the video description below so do check those out. These charts hold a lot of information, you can use them to find the pressure drop per meter, the air velocity, the volume flow rate, and also the size of the ductwork. The layout of the chart does vary a little, depending on the manufacturer, but in this example, the vertical lines are for pressure drop per meter of duct, the horizontal lines are for volume flow rate, the downward diagonal lines are for velocity, and the upward diagonal lines are for duct diameter. We start sizing from the first main duct, which in this example is section A. To limit the noise in this section, we'll specify that you can only have a maximum velocity of five meters per second. We know that this duct also requires a volume flow rate of 0.79 meters cubed per second, so we can use the velocity and volume flow rate to find the missing data on the chart. We take the chart and scroll up from the bottom left until we find the volume flow rate of 0.79 meters cubed per second, then we locate where the velocity line is of five meters per second and we draw a line across until we hit that, then to find the pressure drop, we draw a vertical line down from this intersection. In this instance, we see it comes out at 0.65 pascals per meter, so add this figure to our table. As we are using the equal pressure drop method, we can also use this pressure drop for all the duct lengths, so fill these in too. Then coming back to the chart, we scroll up again and align our intersection with the upward diagonal lines to see that this requires a duct with a diameter of 0.45 meters, so we add that to the table also. We know the volume flow rates and the pressure drop so we can now calculate the values for section C and then also the remaining ducts. For the remainder of the ducts, we need to use the same method. On the chart we start by drawing a line from 0.65 pascals per meter. We draw this line all the way up. Then we draw another line across from where our required volume flow rate is, in this case for section C, we require 0.21 cubic meters per second. At this intersection, we draw a line to find the velocity and we can see that it falls between the lines of three and four meters per second so we need to estimate the value. In this case it seems to be around 3.6 meters per second, so we add that to the chart. Then we draw another line on the other diagonal grid to find our duct diameter, which in this case is around 0.27 meters, and we'll add that to the table also. So just repeat that last process for all the remaining ducts and branches until the table is complete. Now find the total duct losses for each of the ducts and branches, it's very easy and simple to do, just multiply the duct length by the pressure drop per meter of 0.65 pascals per meter and do that for all the ducts and branches on the table. Now we can start on the fittings. The first fitting we'll look at is the 90-degree bend between ducts J and L. For this we look up our lost coefficient from the bend from the manufacturer or from the industry body. Again link's in the video description below for these. In this example, we can see the coefficient comes out at 0.11. We then need to calculate the dynamic loss caused by the bend changing the direction of flow. For that we use the formula Co multiplied by rho, multiplied by V squared divided by two, where Co is our coefficient, rho is the density of the air and V is the velocity. We already know these values, so if we drop these figures in then we get an answer of 0.718 pascals, so just add that to the table. The next fitting will look at is the Tee which connects the main duct to the branches. We'll use the example of the tee with the ID letter H between G and J in the system. Now for this we need to consider that the air is moving in two directions, straight through and also turning off into the branch. So we need to perform calculations for both of these directions. If we look at the air traveling straight through first, we find the velocity ratio first, using the formula velocity out, divided by velocity in. In this example, the air out is 3.3 meters per second, and the air in is four meters per second, which gives us answer of 0.83. Then we perform another calculation to find the area ratio. This uses the formula diameter out squared, divided diameter in squared. In this example, the diameter out is 0.24 meters, and the diameter in is 0.33 meters. So if we square them, we would get 0.53. Now we look up the fitting we're using from the manufacturer or the industry body, again, link's in the video description below for those. In the guides, we find two tables, the one you use depends on the direction of flow, we're using the straight direction, so we'll okay that one and then we look up each ratio to find our last coefficient. Here you can see both values we calculated for between values listed in the table, so we need to perform a bilinear interpolation. To save time, we'll just use an online calculator to find that, links to the site are in the video description below. So we fill out our values and we find the answer of 0.143. Now we calculate the dynamic loss for the straight path with a tee using the formula Co, multiplied by rho, multiplied by V squared divided by two. If we drop our values in, we get the answer of 0.934 pascals so add that to the table. Then we can calculate the dynamic loss for the air which turns into the bend. For this we use the same formulas as before, velocity out, divided by velocity in, to find our velocity ratio. We take our values from our table and use 3.5 meters per second, divided by four meters per second to get 0.875, for the velocity ratio, then we find the area ratio, using the formula diameter out squared, divided by diameter in squared, and we use 0.26 meters squared, divided by 0.33 meters squared to get 0.62 for the area ratio, then we use the bend table for the T section. Again, it's between the values listed in the table, so we have to find the numbers using bilinear interpolation. We drop the values in to get the answer of 0.3645 pascals, so just add that to the table too. Now repeat that calculation for the other tees and fittings until the table is complete. Next, we need to find the index run. which is the run with the largest pressure drop. It's usually the longest run, but it could also be the run with the most fittings. We find it easily by adding up all the pressure losses from start to the exit of each branch. For example, to get from A to C, we lose 5.04 pascals, for A to F, we lose 8.8 pascals, for A to I we lose 10.56 pascals, and for A to L we lose 12.5 pascal. Therefore the fan we use, must overcome the run with the highest loss that being A to L with 12.5 pascals, this being the index run. To balance the system, we need to add dampers to each of the branches to ensure equal pressure drop through all to achieve the design flow rates to each room. We can calculate how much pressure drop each damper needs to provide simply by subtracting the loss of the run from the index run. A to C is 5.04 pascals, which means that branch C would need a damper, providing 7.46 pascals. A to F is 8.8 pascals which means that branch F would require a damper providing 3.7 pascals, and A to I is 10.56 pascals, meaning that duct I, would require a damper providing 1.94 pascals and that is our ductwork system. We'll do another video covering additional ways to improve efficiency in ductwork systems, but unfortunately we've run out of time in this video. Okay guys, that's it for this video. Thank you very much for watching. I hope you've enjoyed this and it has helped you. If so, please don't forget to like, subscribe and share and also check out SimScale software. You can follow us on Facebook, Twitter, Instagram, Google Plus, as well as our website, TheEngineeringMindset.com. Once again, thanks for watching.

Show more

Frequently asked questions

Learn everything you need to know to use airSlate SignNow eSignatures like a pro.

See more airSlate SignNow How-Tos

How can I eSign a contract?

E-signing a contract with airSlate SignNow is fast, easy, and secure. It’s a robust solution for electronically signing and managing documents, contracts and forms. All you have to do is create your account, import a contract, add signature fields (My Signature and/or Signature Field), and send the contract to recipients. When a recipient receives the contract, all they have to do is open their email, click the invitation to sign, create their eSignature, and execute the field you assigned to them. After every party has executed their signature field(s), airSlate SignNow will automatically send everyone involved an executed copy of the contract.

What counts as an electronic signature?

Any symbol on a document can be considered an electronic signature if the signer has confirmed their intention to sign a document and do business digitally. But more importantly, the signature must be associated with the signer. In airSlate SignNow, you can take advantage of the Document History feature and, if necessary, check who and when eSigned your PDF.

How can I get someone to sign my PDF?

Many eSignature services require signers (both senders and recipients) to have accounts, making some processes complicated. airSlate SignNow allows you to collect signatures from anyone, without forcing them to have an account or register in any way. Click Signature Field and select the Send to Sign feature. It opens a pop-up window where you can insert a recipient’s email that needs to eSign your sample. They’ll receive an email and will be able to place their signature on the sample you shared with them. After that, you'll get a notification and a copy of the signed document.
be ready to get more

Get legally-binding signatures now!